TitleApplication of an automatic adaptive filter for Heart Rate Variability analysis
Year2013
Access Date2024, May 19
Secondary TypePRE PI
Number of Files1
Size1005 KiB
2. Context
Author1 Santos, Laurita dos
2 Barroso, Joaquim Jose
3 Macau, Elbert Einstein Nehrer
4 Godoy, M. F. de
Resume Identifier1
2
3 8JMKD3MGP5W/3C9JGUT
Group1
2 LAP-CTE-INPE-MCTI-GOV-BR
3 LAC-CTE-INPE-MCTI-GOV-BR
Affiliation1 Computing and Applied Mathematics Laboratory, National Institute for Space Research, CEP: 12227-010, São José dos Campos, SP, Brazil
2 Instituto Nacional de Pesquisas Espaciais (INPE)
3 Instituto Nacional de Pesquisas Espaciais (INPE)
4 Transdisciplinar Nucleus for Chaos and Complexity Study (NUTECC), Department of Cardiology and Cardiovascular Surgery São José do Rio Preto MedicalSchool, São José do Rio Preto, SP, Brazil
Author e-Mail Address1
2 barroso@plasma.inpe.br
3 elbert@lac.inpe.br
e-Mail Addressmarcelo.pazos@inpe.br
JournalMedical Engineering and Physics
Volume35
Number12
Pages1778-1785
Secondary MarkA1 A2 B1 B1 B1 B1 B2 B2
History (UTC)2018-06-04 03:14:10 :: administrator -> marcelo.pazos@inpe.br :: 2013
3. Content and structure
Is the master or a copy?is the master
Content Stagecompleted
Transferable1
Content TypeExternal Contribution
Version Typepublisher
Keywordsheart rate variability
automatic adaptive filter
time series
AbstractThe presence of artifacts and noise effects in temporal series can seriously hinder the analysis of Heart Rate Variability (HRV). The tachograms should be carefully edited to avoid erroneous interpretations. The physician should carefully analyze the tachogram in order to detect points that might be associated with unlikely biophysical behavior and manually eliminate them from the data series. However, this is a time-consuming procedure. To facilitate the pre-analysis of the tachogram, this study uses a method of data filtering based on an adaptive filter which is quickly able to analyze a large amount of data. The method was applied to 229 time series from a database of patients with different clinical conditions: premature newborns, full-term newborns, healthy young adults, adults submitted to a very-low-calorie diet, and adults under preoperative evaluation for coronary artery bypass grafting. This proposed method is compared to the demanding conventional method, wherein the corrections of occasional ectopic beats and artifacts are usually manually executed by a specialist. To confirm the reliability of the results obtained, correlation coefficients were calculated, using both automatic and manual methods of ltering for each HRV index selected. A high correlation between the results was found, with highly significant p values, for all cases, except for some parameters analyzed in the premature newborns group, an issue that is thoroughly discussed. The authors concluded that the proposed adaptive filtering method helps to efficiently handle the task of editing temporal series for HRV analysis.
AreaFISPLASMA
Arrangement 1urlib.net > BDMCI > Fonds > Produção anterior à 2021 > LABAC > Application of an...
Arrangement 2urlib.net > BDMCI > Fonds > Produção anterior à 2021 > LABAP > Application of an...
doc Directory Contentaccess
source Directory Contentthere are no files
agreement Directory Contentthere are no files
4. Conditions of access and use
Languageen
User Groupadministrator
marcelo.pazos@inpe.br
Reader Groupadministrator
marcelo.pazos@inpe.br
Visibilityshown
Read Permissiondeny from all and allow from 150.163
Update Permissionnot transferred
5. Allied materials
Mirror Repositoryiconet.com.br/banon/2006/11.26.21.31
Next Higher Units8JMKD3MGPCW/3ESGTTP
8JMKD3MGPCW/3ET2RFS
Citing Item Listsid.inpe.br/bibdigital/2013/09.25.21.49 2
sid.inpe.br/mtc-m21/2012/07.13.14.45.07 2
DisseminationPORTALCAPES; COMPENDEX; SCOPUS.
Host Collectionsid.inpe.br/mtc-m21b/2013/09.26.14.25.20
6. Notes
Empty Fieldsalternatejournal archivingpolicy archivist callnumber copyholder copyright creatorhistory descriptionlevel format isbn lineage mark month nextedition notes orcid parameterlist parentrepositories previousedition previouslowerunit progress project rightsholder schedulinginformation secondarydate secondarykey session shorttitle sponsor subject targetfile tertiarymark tertiarytype typeofwork url
7. Description control
e-Mail (login)marcelo.pazos@inpe.br
update 


Close